Product information

Digital Vickers Hardness Tester

DIGITAL VICKERS HARDNESS TESTER
3-VMT-X Series Vickers Hardness Tester
FEATURES

–>AUTO TURRET
Auto turret allows one-touch operation for troublesome lens-indenter-lens changeover required in the measurement.
–>LIQUID CRYSTAL DISPLAY TOUCH PANEL
Large LCD touch panel with a clear display and back light can perform various data processing and other function
–>REPUTED LOADING MECHANISM
Loading mechanism with no fluctuation, “capable to hit aimed portion”, is highly evaluated.
–>HK KNOOP HARDNESS
Knoop hardness calculating functions can be changed over with a one touch panel operation. (HK diamond indenter is optional)
–>TWO OBJECT LENSES CAN BE MOUNTED SIMULTANEOUSLY
In addition to the normal measuring lens(X10 or X20), one more lens of different magnification can be mounted regularly. (Additional lens is optional.)
–>HIGH RIGIDITYBODY ADOPTED
Newly designed VMT-7(7S) can perform high-accuracy measurements with its specially rigidity enhanced body.
–>APPLICABLE TO CE (concurrent engineering)
Safety design applicable to EU low voltage command, EMC command and machine command. Metal fittings are attached as standard to prevent overturning by vibrations caused by earthquake, etc.

SPECIFICATIONS
ITEM CONTENTS
MODEL VMT-X1 VMT-X3 VMT-X7
Test load - 9.807 19.61 29.42 49.03 98.07 196.1 294.2 490.3 N
1 2 3 5 10 20 30 50 kgf
S 2.942 4.903 9.807 29.42 49.03 98.07 196.1 294.2 N
0.3 0.5 1 3 5 10 20 30 kgf
Loading mechanism Automatic loading and releasing method
Turret Manual Automatic
Load applying speed 85 μm/sec
Dwell time 5~40 sec 5~99 sec
Magnification of microscope X 100 (Object lens X 10, eyepiece X 10)
X 200 For 'S' Model (Object lens X 20, eyepiece X 10)
Max. measuring length 100X :999.9 μm (200 x : 600.0μm)
Min.measuring unit 0.1 μm 0.1 μm (200 X ~ 1000 X) , 0.02 μm (100 X)
Max.specimen height 260mm 160mm
Max. specimen depth 160 mm 260 mm
LCD touch-panel Data memory - Max. 999 test data
Hardness conversion - Possible in compliance with ASTM(E-140),JIS.
OK/NG criteria - Upper and lower limits setting, and HI/OK/LOW display.
Data editing - Data output & display: Max value, Min value,
dispersion (R), mean value, standard deviation.
RS-232C
Communication line
- Baud rate: 1200/ 2400/ 4800/ 9600 bps selectable (RS-232C)
Error detection, Parity even/ Parity none selectable (RS-232C)
Data output - 1) Centronics (standard)
2) RS232C or serial output selectable (Factory setting: RS232C)
Accuracy Conform to JIS B7725 and ASTM E-92
Photographic device (optional) Possible to mount at anytime
Dimensions Main body only: W220 x D580 x H770
Weight Approx. 52kg
Power supply Single phase AC 100V 50/60Hz (in Japan)
For overseas: Possible to change up to AC240V)
STANDARD ACCESSORIES
ITEM - S
Hardness standard block 1 1
Diamond indenter(Built in) 1 1
Electronic measuring microscope (With Eyepiece) 1 1
Object lens (Built in) X 10 1 1
X 20 --- 1
Anvil 60mm Ø flat 1 1
V-shape anvil large 1 1
Level adjusting leg 4 4
Small level 1 1
Spare light source bulb (12V, 18W) 2 2
Spare fuse 2 2
Power cord (3P-2.5m) 1 1
Attachment for prevent the machine fall 1 1
Auxiliary tools 1 1
Machine cover 1 1
Instruction Manual 1 1
Accessories box 1 1
ITEM CONTENTS
Knoop indenter Effectively measures thin material
Camera attachment A Polaroid camera adapter need
TV measuring device A TV camera may be mounted on the ocular.
Enlarged indents are measured on the TV monitor and metal
structures are observed easily
Automatic X-stage & PC type
controller VMT-1000PC
Measuring range: X&Y axis each 100mm
Min. movement: 1/100mm
These devices are very effective when we indent continuously.
All operations are controled by PC
Round table Suitable for testing large specimens
Manual X-stage Max. movement: X&Y axis 25mm and 50mm
Precision Vice Max. opening: 50mm and 100mm
Micro test table for jominy test Specimen: Standard size (mm or inch) provided in ISO and JIS
Max. movement: approx. 55mm
Min. micrograduation. 1/10mm or 1/160 inch.
Rotary table This table is usually used on the micro test table with the
precision vice.
Thin specimen measuring device Specimen thickness: 0~5mm
Fine specimen measuring device vertical type For measuring the cross section of fine specimens.
Specimen diameter: 0.1~4 mm.
Fine specimen measuring device
horizontal type
For measuring the cylindrical surface of fine specimens.
Specimen diameter: 0.5~4 mm.
Specimen inclining device type II Vice is not used and a specimen is directly clamped.
The measuring surface always shows a horizontal level and
cause an extremely efficient measuring operation.
Specimen height: 5~21mm
Printer M-3110 From Hardness tester adding up results to data output.